In junctional rhythm, the SA node is no longer in control and the AV node becomes the pacemaker by default due to the property of automaticity. Because the AV node is a less reliable pacemaker, the development of junctional rhythm is cause for concern. The analysis of junctional rhythms is determined by the location of the P waves and the rate.
Because the impulse starts in the AV node, the atria are depolarized in a retrograde manner resulting in an inverted P wave in the upright (positive) leads (such as lead II).

• Inverted P wave before the QRS when the atria depolarize before the ventricles.
• Inverted P wave buried in the QRS when the atria and ventricles depolarize at the same time.
• Inverted P wave after the QRS when the ventricles depolarize before the atria.
• Junctional rhythm: HR 40-60 BPM.
• Accelerated junctional rhythm: HR 60-100 BPM.
• Junctional tachycardia: HR greater than 100 BPM.
Junctional rhythm. HR=52 BPM. QRS=0.08.

Accelerated junctional rhythm. HR=58 BPM. QRS=0.08.

Junctional tachycardia. HR=115 BPM. QRS=0.08.


Junctional rhythms are not infrequently seen in clinical practice. The appearance should always be one of concern because the AV node is less reliable as a pacemaker and because some abnormal clinical condition caused suppression of the SA node.